Use este identificador para citar ou linkar para este item: https://repositorio.ifg.edu.br/handle/prefix/252
Tipo: Trabalho de Conclusão de Curso
Título: Potencial de reuso do efluente tratado por sistema wetland construído
Título(s) alternativo(s): Reuse potential of a constructed wetland system effluent
Autor(es): Silveira, Jéssica Rodrigues
Primeiro Orientador: Pitaluga, Douglas Pereira da Silva
metadata.dc.contributor.referee1: Pitaluga, Douglas Pereira da Silva
metadata.dc.contributor.referee2: Pacheco, Gabriela Cristina Ribeiro
metadata.dc.contributor.referee3: Milograna, Jussanã
metadata.dc.contributor.referee4: Pimenta, Sandro Morais
metadata.dc.contributor.referee5: Almeida, Rogério de Araújo
Resumo: O presente trabalho teve como objetivo avaliar o potencial de reuso do efluente tratado por sistema wetland construído. De modo específico, objetivou- se retomar as atividades de pesquisa na Estação de Pesquisas em Tratamento de Esgotos com Plantas, Câmpus I da Universidade Federal de Goiás, caracterizando as vazões do afluente e dos efluentes desse sistema para comparação dos resultados das análises com as normativas de águas de reuso. Nas análises foram avaliados os parâmetros de cor aparente, turbidez, temperatura, sólidos suspensos totais, sólidos dissolvidos totais, condutividade elétrica, demanda bioquímica de oxigênio, oxigênio dissolvido, pH, dureza, alcalinidade, cloretos, coliformes totais e coliformes termotolerantes. O sistema wetland construído é constituído de um tanque de equalização e um tanque séptico, que encaminham afluente a três leitos independentes, preenchidos com brita # 0, cultivados com macrófitas do tipo Typha latifolia L., seguidos por três filtros independentes de brita # 0, areia fina e solo areno-argiloso. Após trinta dias da aplicação de afluente no sistema, realizaram-se três coletas de amostras simples de sete pontos definidos, sendo uma amostra de afluente, três amostras de efluentes de cada leito com plantas e três, de cada filtro. Os leitos apresentaram percentuais de remoção média de sólidos suspensos totais (87,2%), turbidez (75,3%), cor aparente (61,5%), cloretos (28,1%), alcalinidade (17,7%), sólidos dissolvidos totais (16,9%) e demanda bioquímica de oxigênio (7,6%). Os filtros contribuíram na redução média de sólidos suspensos totais (31,5%), demanda química de oxigênio (29,9%), alcalinidade (28,8%), cloretos (23,7%), condutividade elétrica (21,3%), sólidos dissolvidos totais (19,2%), turbidez (10,0%), dureza (9,5%) e cor aparente (4,6%). Os efluentes finais do sistema wetland construído, nas condições atuais, não estão em conformidade com as normativas de reuso de águas, devido ao processo de tratamento estar na fase de estabilização.
Abstract: The present study had the goal of assessing the reuse potential of the effluent treated by a constructed wetland system. Specifically, the objectives were to return the research activities at the Station for Research on Wastewater Treatment with Plants, Campus I of the Federal University of Goiás, characterizing the flows of the tributary and the effluents of this system to compare the results of the analyzes with the normatives of reuse water. The parameters of apparent color, turbidity, temperature, total suspended solids, total dissolved solids, electrical conductivity, biochemical oxygen demand, dissolved oxygen, pH, hardness, alkalinity, chlorides, total coliforms and thermotolerant coliforms were evaluated. The constructed wetland system consists of an equalization tank and a septic tank, which affluent tributaries to three independent units filled with gravel # 0, grown with Typha latifolia L. macrophytes, followed by three independent filters, consisting of gravel # 0, fine sand and sandy-clay soil. After thirty days of tributary application in the system, three simple sample collections of seven defined points, being one tributary sample, three effluent samples from each unit with plants and three samples from each filter. The percentage of total suspended solids (87.2%), turbidity (75.3%), apparent color (61.5%), chlorides (28.1%), alkalinity (17.7%), total dissolved solids (16.9%) and biochemical oxygen demand (7.6%). The filters contributed to the reduction of total suspended solids (31.5%), chemical oxygen demand (29.9%), alkalinity (28.8%), chlorides (23.7%), electrical conductivity %), total dissolved solids (19.2%), turbidity (10.0%), hardness (9.5%) and apparent color (4.6%). The final effluent from the constructed wetland system, under current conditions, does not comply with water reuse regulations due to the treatment process being in the stabilization phase.
Palavras-chave: Reciclagem de água
reutilização de água
alagados construídos
zona de raízes
CNPq: Engenharia; Engenharia Sanitária; Tratamento de Águas de Abastecimento e Residuárias
Idioma: por
País: Brasil
Editor: Insitituto Federal de Educação, Ciência e Tecnologia de Goiás
Sigla da Instituição: IFG
metadata.dc.publisher.department: Câmpus Goiânia
Citação: SILVEIRA, Jéssica Rodrigues. Potencial de reuso do efluente tratado por sistema wetland construído. Goiânia: Instituto Federal de Educação, Ciência e Tecnologia de Goiás, 2018. 117 f.
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ifg.edu.br/handle/prefix/252
Data do documento: 20-Dez-2018
Aparece nas coleções:Bacharelado em Engenharia Civil

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
tcc_Jéssica Silveira.pdf7,07 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.