Título: Estudo do eletrodo de vidro para o seu reaproveitamento em medições de íons Pb(II)
Título(s) alternativo(s): Study of the glass electrode for its reuse in Pb(ii) ion measurements
Autor(es): Campos Neto, Valmir Gonçalves
Primeiro Orientador: Borges, Elisangela Cardoso de Lima
metadata.dc.contributor.advisor-co1: Sá, Fernando Pereira de
metadata.dc.contributor.referee1: Borges, Elisangela Cardoso de Lima
metadata.dc.contributor.referee2: Sá, Fernando Pereira de
metadata.dc.contributor.referee3: Gobi, Arthur Antonio Santos
Resumo: Este projeto baseia-se nos aspectos teóricos da Eletroquímica e Eletroanalítica. Vale ressaltar que durante a pandemia este projeto foi desenvolvido, incluindo o estudo do eletrodo de pH. O eletrodo de vidro combinado (EVC) quando tem o seu bulbo (membrana de vidro) quebrado ou fissurado ou quando a membrana sensível é inutilizada por efeitos físicos ou químicos irreversíveis, perde completamente a sua função, mesmo que seus componentes elétricos e eletrônicos estejam em perfeito estado, desse modo, o seu reaproveitamento é um fato bem referenciado. Primeiramente, removeu-se a membrana gelatinosa do eletrodo de vidro e a substituiu por uma membrana sólida para detecção de íons Pb(II), denominado-o de eletrodo quimicamente modificado (EQM). Desse modo, o objetivo geral deste projeto é apresentar uma alternativa de reaproveitamento para eletrodos de vidro danificados para serem aplicados em atividades de ensino e pesquisa. Na construção do novo eletrodo, o bulbo quebrado (sensível aos íons H3O+) foi completamente removido e a solução interna de ácido clorídrico escoada. O procedimento a ser executado para a preparação da membrana sólida utilizada na construção do EIS a Pb(II) seguiu uma replicação do trabalho de Silva, Lehmkuhl e Alcanfor (2009) por meio da precipitação do sulfeto de prata (Ag2S) e do sulfeto de chumbo (PbS). Ensaios de curva de calibração e testes de eficiência nos eletrodos diagnosticaram um rápido desgaste do EQM mas uma elevada sensibilidade para íons Pb(II) em meio com ajuste de força iônica quanto ao EVC a o slope nernstiniano está dentro do padrão aceitável na condição ótima - valor de 93% mas ressalta-se a importância no modo de preservação tanto das soluções tampão para verificação da calibração e da membrana do eletrodo (EVC).
Abstract: This project is based on the theoretical aspects of Electrochemistry and Electroanalytics. It is worth noting that during the pandemic this project was developed, including the study of the pH electrode. The combined glass electrode (EVC) when it has its bulb (glass membrane) broken or cracked, or when the sensitive membrane is rendered useless by irreversible physical or chemical effects, completely loses its function, even if its electrical and electronic components are in perfect condition, so its reuse is a well referenced fact. First, the gelatinous membrane of the glass electrode was removed and replaced by a solid membrane for detection of Pb(II) ions, called the modified chemical electrode (MCE). Thus, the general objective of this project is to present an alternative of reuse for damaged glass electrodes to be applied in teaching and research activities. In the construction of the new electrode, the broken bulb (sensitive to H3O+ions) was completely removed and the internal hydrochloric acid solution drained. The procedure to be performed for the preparation of the solid membrane used for the construction of the Pb(II) EIS followed a replication of the work of Silva, Lehmkuhl and Alcanfor (2009) by precipitation of silver sulfide (Ag2S) and lead sulfide (PbS). Calibration curve assays and efficiency tests on the electrodes diagnosed a rapid wear of the EQM but a high sensitivity for Pb(II) ions in ionic strength adjusted medium as for the EVC a the nernstinian slope is within the acceptable standard in the optimum condition - value of 93% but the importance in the preservation mode of both the buffer solutions for calibration verification and the electrode membrane (EVC) is emphasized.
Palavras-chave: Eletrodo de vidro
Eletrodo modificado
Chumbo
Reaproveitamento
CNPq: CNPQ::CIENCIAS EXATAS E DA TERRA
Idioma: por
País: Brasil
Editor: Insitituto Federal de Educação, Ciência e Tecnologia de Goiás
Sigla da Instituição: IFG
metadata.dc.publisher.department: Câmpus Inhumas
Citação: CAMPOS NETO, Valmir Gonçalves. Estudo do eletrodo de vidro para o seu reaproveitamento em medições de íons Pb(II). 2021. Trabalho de Conclusão de Curso (Licenciatura em Química) - Instituto Federal de Goiás, Inhumas, 2021.
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ifg.edu.br:8080/handle/prefix/817
Data do documento: 18-Ago-2021
Aparece nas coleções:Licenciatura em Química

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TCC valmir Correto cd.pdfTCC Valmir - com termo de autorização2,35 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.