Use este identificador para citar ou linkar para este item:
https://repositorio.ifg.edu.br/handle/prefix/632| Tipo: | Trabalho de Conclusão de Curso |
| Título: | Análise comparativa teórico-experimental entre as principais topologias utilizadas em aterramentos elétricos |
| Título(s) alternativo(s): | Theoretical-experimental comparative analysis between the main topologies used in electrical groundings |
| Autor(es): | Morais, Filipe Santana de |
| Primeiro Orientador: | Mendonça, Roberlam Gonçalves de |
| metadata.dc.contributor.referee1: | Mendonça, Roberlam Gonçalves de |
| metadata.dc.contributor.referee2: | Pacheco, Cláudio Roberto |
| metadata.dc.contributor.referee3: | Bernardeli, Victor Regis |
| Resumo: | Para validação de conceitos relacionados a aterramentos elétricos é de suma importância a realização de testes e análises práticas. Sendo assim, este trabalho tem o objetivo de realizar uma análise comparativa teórica-experimental entre as topologias clássicas de aterramentos elétricos: hastes alinhadas, triângulo, quadrado e circunferência. Para desenvolvimento do estudo, o trabalho é dividido em sete etapas, entre elas tem-se o embasamento teórico, medições de campo e estratificação do solo, simulações computacionais, implementação prática, medições de resistências dos sistemas de aterramentos, análise comparativa teórica-experimental e conclusões. Através do estudo de cada topologia é possível verificar a influência de fatores como espaçamento, quantidade, comprimento e diâmetro das hastes. Por meio dos resultados obtidos as expectativas foram atendidas. A discrepância entre resultados teóricos e experimentais foram devidos a condições climáticas (temperatura e umidade) do solo, existência de tubulações hidráulicas e elétricas no terreno estudado, imperfeições de alinhamento e distâncias das hastes de cada malha, além da existência de muitas pedras e possíveis cupinzeiros internos ao solo. Entre as topologias estudadas, o sistema desenvolvido em circunferência apresentou os melhores resultados teóricos e experimentais, se comparada as demais topologias desenvolvidas. |
| Abstract: | For the validation of concepts related to electrical grounds, it is extremely important to carry out tests and practical analyzes. Therefore, this work aims to carry out a theoreticalexperimental comparative analysis between the classic topologies of electrical grounds: aligned rods, triangle, square and circumference. For the development of the study, the work is divided into seven stages, among which there is the theoretical basis, field measurements and soil stratification, computer simulations, practical implementation, resistance measurements of the grounding systems, theoretical-experimental comparative analysis and conclusions. Through the study of each topology it is possible to verify the influence of factors such as spacing, quantity, length and diameter of the rods. Through the results obtained, expectations were met. The discrepancy between theoretical and experimental results was due to climatic conditions (temperature and humidity) of the soil, existence of hydraulic and electrical pipes in the studied terrain, imperfections of alignment and distances of the rods of each mesh, in addition to the existence of many stones and possible termite mounds internal to the ground. Among the studied topologies, the system developed in circumference presented the best theoretical and experimental results, when compared to the other developed topologies. |
| Palavras-chave: | Topologias de aterramentos Grounding topologies Malhas isoladas Isolated meshes Comparativo teórico-experimental Theoretical-experimental comparison |
| CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA::MEDICAO, CONTROLE, CORRECAO E PROTECAO DE SISTEMAS ELETRICOS DE POTENCIA |
| Idioma: | por |
| País: | Brasil |
| Editor: | Insitituto Federal de Educação, Ciência e Tecnologia de Goiás |
| Sigla da Instituição: | IFG |
| metadata.dc.publisher.department: | Câmpus Itumbiara |
| Citação: | MORAIS, Filipe Santana de. Análise comparativa teórico-experimental entre as principais topologias utilizadas em aterramentos elétricos. 2021. Trabalho de Conclusão de Curso (Graduação em Bacharelado em Engenharia Elétrica) – Instituto Federal de Educação, Ciência e Tecnologia de Goiás - IFG, Itumbiara, 104 p. 2021. |
| Tipo de Acesso: | Acesso Aberto |
| URI: | http://repositorio.ifg.edu.br/handle/prefix/632 |
| Data do documento: | 21-Jan-2021 |
| Aparece nas coleções: | Bacharelado em Engenharia Elétrica |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| TCC Engenharia Elétrica Itumbiara 2021 - Filipe Santana de Morais.pdf | TCC Engenharia Elétrica Câmpus Itumbiara - 2021 - Análise comparativa teórico-experimental entre as principais topologias utilizadas em aterramentos elétricos | 5,57 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.