| Título: | Iluminação no ambiente escolar: análise luminotécnica de salas de aulas do IFG-Itumbiara (GO) |
| Título(s) alternativo(s): | Lighting in the school environment: lighting analysis of classrooms at IFG-Itumbiara (GO) |
| Autor(es): | Lima, Niele Alves |
| Primeiro Orientador: | Resende, Diogo Soares |
| metadata.dc.contributor.referee1: | Bernardeli, Victor Regis |
| metadata.dc.contributor.referee2: | Prado, Wellington do |
| metadata.dc.contributor.referee3: | Resende, Diogo Soares |
| Resumo: | Este trabalho apresenta a avaliação das condições de iluminação artificial em salas de aula do bloco antigo do Instituto Federal de Goiás – Câmpus Itumbiara, por meio de medições de iluminância realizadas in loco. O objetivo do estudo consistiu em verificar a conformidade do sistema de iluminação existente com os critérios técnicos estabelecidos pela ABNT NBR ISO/CIE 8995-1:2013, aplicáveis a ambientes educacionais noturnos. A metodologia adotada compreendeu pesquisa bibliográfica, levantamento das características físicas e construtivas das salas analisadas e medições ponto a ponto dos níveis de iluminância no plano de trabalho, conforme os procedimentos recomendados pela norma. Os dados obtidos foram organizados e analisados quantitativamente, considerando os valores de iluminância média, mínima e máxima, bem como o índice de uniformidade da iluminação. Os resultados indicaram que todas as salas avaliadas apresentaram iluminância média inferior ao valor mínimo recomendado para salas de aula utilizadas no período noturno, além de índices de uniformidade significativamente abaixo dos parâmetros normativos. Observou-se, ainda, uma distribuição luminosa desigual, com maiores níveis de iluminância concentrados nas proximidades das luminárias e valores reduzidos em áreas periféricas. Portanto, o sistema de iluminação artificial analisado não atende plenamente aos requisitos estabelecidos pela norma vigente, evidenciando a importância de avaliações técnicas periódicas em ambientes educacionais. |
| Abstract: | This study presents an evaluation of the artificial lighting conditions in classrooms of the old block of the Federal Institute of Goiás – Itumbiara Campus, based on in situ illuminance measurements. The objective of the study was to verify the compliance of the existing lighting system with the technical criteria established by ABNT NBR ISO/CIE 8995-1:2013, applicable to educational environments used at night. The adopted methodology included a bibliographic review, a survey of the physical and constructive characteristics of the analyzed classrooms, and point-by-point measurements of illuminance levels on the work plane, in accordance with the procedures recommended by the standard. The collected data were organized and quantitatively analyzed, considering average, minimum, and maximum illuminance values, as well as the lighting uniformity index. The results indicated that all evaluated classrooms presented average illuminance levels below the minimum recommended value for classrooms used during the nighttime period, in addition to uniformity indices significantly lower than the normative parameters. An uneven luminous distribution was also observed, with higher illuminance levels concentrated near the luminaires and reduced values in peripheral areas. It is concluded that the analyzed artificial lighting system does not fully comply with the requirements established by the current standard, highlighting the importance of periodic technical evaluations in educational environments. |
| Palavras-chave: | Iluminação artificial. Artificial lighting. Avaliação luminotécnica. Lighting assessment. Salas de aula. Classrooms. Iluminância. Illuminance. Uniformidade luminosa. Lighting uniformity. |
| CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA::INSTALACOES ELETRICAS PREDIAIS E INDUSTRIAIS |
| Idioma: | por |
| País: | Brasil |
| Editor: | Insitituto Federal de Educação, Ciência e Tecnologia de Goiás |
| Sigla da Instituição: | IFG |
| metadata.dc.publisher.department: | Câmpus Itumbiara |
| Citação: | LIMA, Niele Alves. Iluminação no ambiente escolar: análise luminotécnica de salas de aulas do IFG-Itumbiara (GO). Orientador: Diogo Soares Resende. 2026. 73 p. Trabalho de Conclusão de Curso (Graduação em Bacharelado em Engenharia Elétrica) – Instituto Federal de Educação, Ciência e Tecnologia de Goiás - IFG, Itumbiara, 2026. |
| Tipo de Acesso: | Acesso Aberto |
| URI: | https://repositorio.ifg.edu.br/handle/prefix/2803 |
| Data do documento: | 10-Fev-2026 |
| Aparece nas coleções: | Bacharelado em Engenharia Elétrica |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| tcc_Niele Alves Lima.pdf | TCC Bacharelado em Engenharia Elétrica - Câmpus Itumbiara 2026 – Niele Alves Lima - Iluminação no ambiente escolar: análise luminotécnica de salas de aulas do IFG-Itumbiara (GO). | 2,54 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.