| Título: | Dimensionamento de um SPDA para a quadra poliesportiva do Instituto Federal de Goiás, Campus Itumbiara: estudo de caso. |
| Título(s) alternativo(s): | Design of a lightning protection system for the multi-sports court at the Federal Institute of Goiás, Itumbiara Campus: a case study. |
| Autor(es): | Ferreira, Thássio Lima |
| Primeiro Orientador: | Prado, Wellington do |
| metadata.dc.contributor.referee1: | Bernardeli, Victor Regis |
| metadata.dc.contributor.referee2: | Souza, Williamar Prazeres |
| metadata.dc.contributor.referee3: | Prado, Wellington do |
| Resumo: | As descargas atmosféricas representam risco significativo para pessoas, edificações, instalações elétricas e equipamentos, especialmente em estruturas metálicas e ambientes destinados à circulação de usuários. Nesse contexto, este trabalho tem como objetivo dimensionar um Sistema de Proteção contra Descargas Atmosféricas (SPDA) para a quadra poliesportiva do Instituto Federal de Goiás — Campus Itumbiara, com base nos critérios estabelecidos pela ABNT NBR 5419:2026. A pesquisa foi desenvolvida por meio de estudo de caso aplicado, com levantamento teórico, análise normativa, inspeção em campo, identificação das características físicas da estrutura, medições elétricas, análise de risco e dimensionamento dos subsistemas de captação, descida, aterramento, equipotencialização e proteção interna. A quadra analisada possui cobertura metálica, estrutura robusta, pilares distribuídos ao longo do perímetro, grades e telas metálicas acessíveis aos usuários, além de alimentação elétrica para iluminação. A análise de risco considerou principalmente o risco R1, relacionado à perda de vida humana ou ferimentos permanentes, obtendo-se valor inferior ao risco tolerável previsto pela norma. Ainda assim, em razão do uso coletivo da edificação, da presença de alunos e servidores, das partes metálicas acessíveis e das exigências de segurança aplicáveis, adotou-se o Nível de Proteção II (NP II) para o dimensionamento do SPDA. Os resultados indicaram a possibilidade de aproveitamento da cobertura metálica como componente natural de captação, dos pilares e elementos estruturais como descidas naturais e das fundações como eletrodos naturais de aterramento. Também foi identificada a necessidade de equipotencialização das grades e telas metálicas, em razão da diferença de potencial observada entre esses elementos e a estrutura principal, bem como a recomendação de instalação de dispositivos de proteção contra surtos no quadro de iluminação. Conclui-se que a solução proposta contribui para a redução dos riscos associados às descargas atmosféricas, melhora a segurança dos usuários e adequa a estrutura aos critérios técnicos da ABNT NBR 5419:2026. |
| Abstract: | Lightning strikes represent a significant risk to people, buildings, electrical installations and equipment, especially in metallic structures and areas intended for user circulation. In this context, this study aims to design a Lightning Protection System (LPS) for the sports court of the Federal Institute of Goiás — Itumbiara Campus, based on the criteria established by ABNT NBR 5419:2026. The research was developed through an applied case study, including bibliographic review, standards analysis, field inspection, identification of the physical characteristics of the structure, electrical measurements, risk assessment and design of the airtermination, down-conductor, earthing, equipotential bonding and internal protection subsystems. The analyzed sports court has a metallic roof, robust structure, columns distributed along its perimeter, metallic fences and screens accessible to users, as well as an electrical supply for lighting. The risk assessment mainly considered risk R1, related to loss of human life or permanent injury, resulting in a value lower than the tolerable risk established by the standard. Nevertheless, due to the collective use of the building, the presence of students and staff, accessible metallic parts and applicable safety requirements, Lightning Protection Level II (LPL II) was adopted for the LPS design. The results indicated the possibility of using the metallic roof as a natural air-termination component, the columns and structural elements as natural down-conductors, and the foundations as natural earthing electrodes. The need for equipotential bonding of the metallic fences and screens was also identified, due to the potential difference observed between these elements and the main structure, as well as the recommendation to install surge protective devices in the lighting distribution board. It is concluded that the proposed solution contributes to reducing risks associated with lightning strikes, improves user safety and adapts the structure to the technical criteria of ABNT NBR 5419:2026. |
| Palavras-chave: | Descargas atmosféricas. Lightning strikes. SPDA. Lightning protection system. Análise de risco. Risk assessment. Equipotencialização. Equipotential bonding. ABNT NBR 5419:2026. |
| CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA::MEDICAO, CONTROLE, CORRECAO E PROTECAO DE SISTEMAS ELETRICOS DE POTENCIA |
| Idioma: | por |
| País: | Brasil |
| Editor: | Insitituto Federal de Educação, Ciência e Tecnologia de Goiás |
| Sigla da Instituição: | IFG |
| metadata.dc.publisher.department: | Câmpus Itumbiara |
| Citação: | FERREIRA, Thássio Lima. Dimensionamento de um SPDA para a quadra poliesportiva do Instituto Federal de Goiás, Campus Itumbiara: estudo de caso. Orientador: Wellington do Prado. 2026. 77 p. Trabalho de Conclusão de Curso (Graduação em Bacharelado em Engenharia Elétrica) – Instituto Federal de Educação, Ciência e Tecnologia de Goiás - IFG, Itumbiara, 2026. |
| Tipo de Acesso: | Acesso Aberto |
| URI: | https://repositorio.ifg.edu.br/handle/prefix/2802 |
| Data do documento: | 10-Jul-2026 |
| Aparece nas coleções: | Bacharelado em Engenharia Elétrica |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| tcc_Thássio Lima Ferreira.pdf | TCC Bacharelado em Engenharia Elétrica - Câmpus Itumbiara 2026 – Thássio Lima Ferreira - Dimensionamento de um SPDA para a quadra poliesportiva do Instituto Federal de Goiás, Campus Itumbiara: estudo de caso. | 2,55 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.