Use este identificador para citar ou linkar para este item:
https://repositorio.ifg.edu.br/handle/prefix/590| Tipo: | Trabalho de Conclusão de Curso |
| Título: | Estudo de técnicas anti-ilhamento ativas e passivas com foco na redução da zona de não detecção |
| Título(s) alternativo(s): | Study of active and passive anti-slanding techniques based on the reduction of their non-detection zone |
| Autor(es): | Silveira, Eddie Martins |
| Primeiro Orientador: | Chaves, Eric Nery |
| metadata.dc.contributor.referee1: | Chaves, Eric Nery |
| metadata.dc.contributor.referee2: | Viajante, Ghunter Paulo |
| metadata.dc.contributor.referee3: | Freitas, Marcos Antônio Arantes de |
| Resumo: | Atualmente, novas tecnologias para geração de energia são avaliadas e desenvolvidas, entre as quais destacam-se a geração distribuída, onde as unidades geradoras são instaladas nos pontos de consumo do sistema de distribuição de energia, sendo os sistemas fotovoltaicos um dos mais difundidos. Devido a sua aceitação e seu rápido crescimento, novos desafios têm surgido para que a qualidade da energia elétrica seja mantida, com destaque para o fenômeno do ilhamento, onde parte do sistema elétrico se mantém em operação, apesar de sua desconexão com a fonte de energia principal. Assim, para que as centrais geradoras distribuídas possam garantir a segurança humana e dos dispositivos conectados à rede elétrica, o inversor precisa possuir, conforme legislação, função anti-ilhamento a fim de se desconectar do sistema elétrico caso ocorra o ilhamento. Portanto, este trabalho analisa tal função, também chamada de técnica anti-ilhamento, distribuídas em duas categorias, onde, para as técnicas locais passivas, são avaliados três métodos (sub/sobrefrequência, sub/sobretensão e detecção por salto de fase) e, para as técnicas locais ativas, são avaliados dois métodos (desvio ativo de frequência e desvio ativo de frequência com feedback positivo). A análise se dará por meio de simulação computacional e tem como objetivo observar a zona de não detecção e o tempo de acionamento de cada técnica para que possam ser consideradas as mais eficazes e sugerir meios para contornar as principais limitações de cada método. |
| Abstract: | Nowadays, new technologies for power generation have been evaluated and developed, which the most prominent are the distributed generation, where the generating power units are installed at the points of consumption of the distribution system, with photovoltaic systems being one of the most widespread of them. Due to its acceptance and fast growth, new challenges have arisen in order to maintain the electric power’s quality, with emphasis on the islanding phenomenon, where part of the electric power system remains in operation, despite its disconnection from the main power source. Thus, for the distributed generating plants to guarantee human and devices connected to the electrical network’s security, the inverter must have, according to the law, an anti-islanding function in order to disconnect itself from the electric power system in case of islanding. Therefore, this work analyzes this function, also called anti-islanding technique, distributed in two categories, where, for passive local techniques, three methods are evaluated (under/overfrequency, under/overvoltage and phase jump detection) and, for active local techniques, two methods are evaluated (active frequency drift and active frequency drift with positive feedback). The analysis will take place through computer simulation and it aims to observe the non-detection zone and the trip time of each technique so that the most effective ones can be considered and it can be proposed ways to get around the main limitations of each method. |
| Palavras-chave: | Sistema fotovoltaico Photovoltaic system Geração distribuída Distributed generation Técnica anti-ilhamento Anti-islanding technique Desvio ativo de frequência Active frequency drift Detecção por salto de fase Phase jump detection Zona de não detecção Non-detection zone |
| CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA::MEDICAO, CONTROLE, CORRECAO E PROTECAO DE SISTEMAS ELETRICOS DE POTENCIA |
| Idioma: | por |
| País: | Brasil |
| Editor: | Insitituto Federal de Educação, Ciência e Tecnologia de Goiás |
| Sigla da Instituição: | IFG |
| metadata.dc.publisher.department: | Câmpus Itumbiara |
| Citação: | SILVEIRA, Eddie Martins da. Estudo de Técnicas anti-ilhamento ativas e passivas com foco na redução da zona de não detecção. 2020. Trabalho de conclusão de curso (Bacharelado em Engenharia Elétrica) - Instituto Federal de Educação, Ciência e Tecnologia de Goiás, Itumbiara, Goiás, 123 p. 2020. |
| Tipo de Acesso: | Acesso Aberto |
| URI: | http://repositorio.ifg.edu.br/handle/prefix/590 |
| Data do documento: | 28-Out-2020 |
| Aparece nas coleções: | Bacharelado em Engenharia Elétrica |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| Eddie Martins da Silveira - TCC Engenharia Elétrica.pdf | TCC Bacharelado em Engenharia Elétrica - Estudo de técnicas anti-ilhamento ativas e passivas com foco na redução da zona de não detecção | 4,89 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.