dc.description.abstractIn this paper, Volt-VAr control in unbalanced four-wire medium voltage distribution network is performed. The objective is to minimize power losses in the distribution network by allocating capacitors and adjusting TAPs of the voltage regulators installed. Reactive power and unbalance cause power losses in unbalanced networks. The technique used in this paper is capacitor allocation by ideal compensation method that compensates for reactive and unbalance in the network. Voltage regulators are adjusted to regulate the voltage within the allowed range. Tests are performed for IEEE 34 bus unbalanced network. Cases with rated load and increased unbalance of loads are tested. The power losses minimization is obtained by dispersed search metaheuristic. The results of the method used present a greater reduction in power losses and compensation for losses in the neutral conductor in relation to the base case and in relation to the balanced capacitor bank allocation.pt_BR
dc.description.resumoNeste artigo é realizado o controle Volt-VAr em uma rede de distribuição de média tensão desequilibrada a quatro fios. O objetivo é minimizar as perdas elétricas na rede de distribuição pela alocação de capacitores e pelo ajuste dos TAPs dos reguladores de tensão pré-instalados. A potência reativa e o desequilíbrio causam perdas elétricas em redes desequilibradas. A técnica utilizada neste trabalho é a alocação de capacitores pelo método de compensação ideal que compensa os reativos e o desequilíbrio na rede. Os reguladores de tensão são ajustados para regular a tensão dentro da faixa permitida. Os testes são feitos para a rede desequilibrada IEEE 34 barras. São testados casos com carga nominal e aumento do desequilíbrio das cargas. A minimização das perdas elétricas é obtida pela meta-heurística busca dispersa. Os resultados do método utilizado apresentam uma maior redução das perdas elétricas e a compensação das perdas no condutor neutro em relação ao caso base e em relação à alocação de banco de capacitores equilibrados.pt_BR
dc.description.provenanceSubmitted by Marcelo Semensato (marcelo.semensato@ifg.edu.br) on 2026-03-03T22:52:00Z No. of bitstreams: 4 trab evento Marcelo Semensato.pdf: 1890681 bytes, checksum: 04026eef233696d3b199ace2acdb8463 (MD5) termo_autorizaca Marcelo.pdf: 160866 bytes, checksum: 75dbe9f9a4a1d680d063d184351f4441 (MD5) termo_autorizaca Rezende.pdf: 184131 bytes, checksum: b32438dbb9651e4b9cf5b405c9f1be75 (MD5) termo_autorizaca Lambert.pdf: 164459 bytes, checksum: 2e1777f2587962f4695fed370578cc76 (MD5)en
dc.description.provenanceApproved for entry into archive by Suzane Goncalves Duarte Peixoto (suzane.duarte@ifg.edu.br) on 2026-03-24T13:25:59Z (GMT) No. of bitstreams: 4 trab evento Marcelo Semensato.pdf: 1890681 bytes, checksum: 04026eef233696d3b199ace2acdb8463 (MD5) termo_autorizaca Marcelo.pdf: 160866 bytes, checksum: 75dbe9f9a4a1d680d063d184351f4441 (MD5) termo_autorizaca Rezende.pdf: 184131 bytes, checksum: b32438dbb9651e4b9cf5b405c9f1be75 (MD5) termo_autorizaca Lambert.pdf: 164459 bytes, checksum: 2e1777f2587962f4695fed370578cc76 (MD5)en
dc.description.provenanceMade available in DSpace on 2026-03-24T13:25:59Z (GMT). No. of bitstreams: 4 trab evento Marcelo Semensato.pdf: 1890681 bytes, checksum: 04026eef233696d3b199ace2acdb8463 (MD5) termo_autorizaca Marcelo.pdf: 160866 bytes, checksum: 75dbe9f9a4a1d680d063d184351f4441 (MD5) termo_autorizaca Rezende.pdf: 184131 bytes, checksum: b32438dbb9651e4b9cf5b405c9f1be75 (MD5) termo_autorizaca Lambert.pdf: 164459 bytes, checksum: 2e1777f2587962f4695fed370578cc76 (MD5) Previous issue date: 2024-10-18en
dc.languageporpt_BR
dc.publisherUniversidade Federal do Rio de Janeiropt_BR
dc.publisher.countryBrasilpt_BR
dc.relation.ispartofCongresso Brasileiro de Automática CBApt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectAlocação de capacitorespt_BR
dc.subjectmeta-heurística busca dispersapt_BR
dc.subjectmétodo de compensação idealpt_BR
dc.subjectcompensação da corrente do neutropt_BR
dc.subjectrede de distribuição desequilibradapt_BR
dc.subjectregulador de tensãopt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA ELETRICApt_BR
dc.titleControle Volt-VAr em Rede de Distribuição Desequilibrada Utilizando o Método de Compensação Idealpt_BR
dc.title.alternativeVolt-VAR Control in Unbalanced Distribution Network Using the Ideal Compensation Methodpt_BR
dc.typeTrabalho Completopt_BR
ifg.linktrabalhohttps://www.sba.org.br/open_journal_systems/index.php/cba/article/view/4512pt_BR
Aparece nas coleções:Eventos realizados extra IFG

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
trab evento Marcelo Semensato.pdfTrabalho completo evento CBA 20241,85 MBAdobe PDFVisualizar/Abrir
termo_autorizaca Marcelo.pdfTermo autorização Semensato157,1 kBAdobe PDFVisualizar/Abrir
termo_autorizaca Rezende.pdfTermo autorização Rezende179,82 kBAdobe PDFVisualizar/Abrir
termo_autorizaca Lambert.pdfTermo autorização Lambert160,6 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.