Use este identificador para citar ou linkar para este item:
https://repositorio.ifg.edu.br/handle/prefix/2218| Tipo: | Trabalho de Conclusão de Curso |
| Título: | Análise do calor de hidratação do concreto em bases de aerogeradores: estudo de caso |
| Título(s) alternativo(s): | nalysis of the heat of hydration of concrete in bases of wind generators: case study |
| Autor(es): | Sousa, Jordana Rocha |
| Primeiro Orientador: | Almeida, Marina Augusta M. de |
| metadata.dc.contributor.advisor-co1: | Santos, Fábio |
| metadata.dc.contributor.referee1: | Almeida, Marina Augusta Malagoli de |
| metadata.dc.contributor.referee2: | Bueno, Mônica Emerenciano |
| metadata.dc.contributor.referee3: | Gonçalves, Vítor |
| Resumo: | O avanço das tecnologias de construção de torres eólicas resultou em aerogeradores de maiores alturas e, por consequência, maiores volumes de fundações, sendo este intimamente ligado com o calor de hidratação do concreto. Os métodos de resfriamento são utilizados diante da necessidade de diminuir o calor gerado pelo concreto massa, sendo assim, este trabalho propõe uma análise estatística, relacionada ao calor de hidratação e as variáveis envolvidas em uma comparação com os reais comportamentos, a partir da verificação da temperatura de concretagem de bases de aerogeradores, em uma situação de estudo de caso de um parque eólico localizado no Rio Grande do Norte - Brasil. Foram propostas análises das concretagens de 62 bases de aerogeradores, a partir do software MATLAB®, a fim de traçar o comportamento verificado pelos dados da amostra. Como resultados, a análise de variáveis aleatórias mostrouse mais favorável pelas diferentes condições as quais as fundações estão submetidas. As análises comprovaram a eficiência do método de resfriamento utilizando a adição de gelo ao emassamento e o atendimento ao modelo de comportamento previsto |
| Abstract: | The advancement of wind tower construction technologies resulted in wind turbines with greater heights and, consequently, greater volumes of foundations, which is closely linked with the heat of hydration of concrete. Cooling methods are used in view of the need to reduce the heat generated by the concrete mass, therefore, this work proposes a statistical analysis, related to the hydration heat and the variables involved in a comparison with the real behaviors, from the verification of the concreting temperature of wind turbine bases, in a case study situation of a wind farm located in Rio Grande do Norte - Brazil. Analyzes of the concreting of 62 bases of wind turbines were proposed, from the MATLAB® software, in order to trace the behavior verified by the sample data. As a result, the analysis of random variables proved to be more favorable due to the different conditions to which foundations are subjected. The analyzes proved the efficiency of the cooling method using the addition of ice to the mix and the fulfillment of the predicted behavior model. |
| Palavras-chave: | Torres eólicas Wind towers Calor de hidratação Heat of hydration Métodos de resfriamento Cooling methods Concreto massa Mass concrete |
| CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::ESTRUTURAS::ESTRUTURAS DE CONCRETO |
| Idioma: | por |
| País: | Brasil |
| Editor: | Insitituto Federal de Educação, Ciência e Tecnologia de Goiás |
| Sigla da Instituição: | IFG |
| metadata.dc.publisher.department: | Câmpus Jataí |
| Citação: | SOUSA, Jordana Rocha. Análise do calor de hidratação do concreto em bases de aerogeradores: estudo de caso. 2023. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) - Instituto Federal de Goiás, Jataí. 2023. |
| Tipo de Acesso: | Acesso Aberto |
| URI: | http://repositorio.ifg.edu.br:8080/handle/prefix/2218 |
| Data do documento: | 30-Mai-2023 |
| Aparece nas coleções: | Bacharelado em Engenharia Civil |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| tcc_Jordana Rocha Sousa.pdf | TCC | 5,64 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.