Use este identificador para citar ou linkar para este item:
https://repositorio.ifg.edu.br/handle/prefix/1816Registro completo de metadados
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.coverage.spatial | São Mateus | pt_BR |
| dc.creator | Semensato, Marcelo | - |
| dc.creator | Rezende, Jaqueline Oliveira | - |
| dc.creator | Lambert, José Antônio | - |
| dc.creator.Lattes | http://lattes.cnpq.br/5295785760443137 | pt_BR |
| dc.date.accessioned | 2024-01-12T18:03:06Z | - |
| dc.date.available | 2024-01-12T18:03:06Z | - |
| dc.date.issued | 2023-12-28 | - |
| dc.identifier.citation | Semensato, M.; Rezende, J. O.; and Lambert, J. A. "Passive filters allocation in unbalanced distribution network with high penetration of distributed generation". Lat. Am. J. Energy Res, vol. 10, n. 2, pp. 23-33, 2023. | pt_BR |
| dc.citation.volume | 10 | pt_BR |
| dc.citation.issue | 2 | pt_BR |
| dc.citation.spage | 23 | pt_BR |
| dc.citation.epage | 33 | pt_BR |
| dc.identifier.doi | https://doi.org/10.21712/lajer.2023.v10.n2.p23-33 | pt_BR |
| dc.identifier.issn | 2358-2286 | pt_BR |
| dc.identifier.uri | http://repositorio.ifg.edu.br:8080/handle/prefix/1816 | - |
| dc.description.abstract | O objetivo deste artigo é a alocação de filtros passivos em uma rede de energia desequilibrada com alta penetração de geração distribuída para minimizar os custos de perdas elétricas nas linhas de distribuição, incluindo perdas causadas por componentes harmônicos e perdas no condutor neutro devido às cargas desequilibradas. . As componentes harmônicas e a corrente fundamental entregue pela geração distribuída provocam um aumento de tensão no barramento de geração, e as tensões na rede acima do limite permitido pela norma são reduzidas através da alocação de filtros passivos sem corte da potência ativa na geração distribuída. A compensação do desequilíbrio e da potência reativa é realizada pelo método de compensação ideal aplicado à rede de distribuição. Os testes são realizados para a rede IEEE 34 barras, sendo o quarto fio da simulação o neutro isolado. A meta-heurística busca dispersa aplicada na simulação tende a minimizar os custos das perdas elétricas nas linhas e os custos dos filtros passivos alocados na rede de distribuição de média tensão, atendendo às restrições operacionais da rede. | pt_BR |
| dc.description.resumo | The purpose of this paper is the allocation of passive filters in an unbalanced power network with high penetration of distributed generation to minimize the costs of power losses in the distribution lines, including power losses caused by harmonic components and neutral conductor power losses due to unbalanced loads. The harmonic components and the fundamental current generated by the distributed generation cause a voltage increase in the generation bus, and the voltages in the network above the limit allowed by standard are reduced by allocating passive filters without cutting the active power in the distributed generation. The unbalance and reactive power compensation is performed by the ideal compensation method applied to the distribution network. The tests are for the IEEE 34 bus network, with the fourth wire in the simulation being the isolated neutral. The scatter search metaheuristic applied in the simulation tends to minimize the costs of power losses in the lines and the costs of the passive filters allocated in the medium voltage distribution network, meeting the operational constraints of the network. | pt_BR |
| dc.description.provenance | Submitted by Marcelo Semensato (marcelo.semensato@ifg.edu.br) on 2024-01-03T18:18:47Z No. of bitstreams: 1 SemensatoETAL_Lajer_2023-2.pdf: 1274576 bytes, checksum: 0e0e7b97e41361a07200c3a5c4af32bf (MD5) | en |
| dc.description.provenance | Approved for entry into archive by Suzane Goncalves Duarte Peixoto (suzane.duarte@ifg.edu.br) on 2024-01-12T18:03:06Z (GMT) No. of bitstreams: 1 SemensatoETAL_Lajer_2023-2.pdf: 1274576 bytes, checksum: 0e0e7b97e41361a07200c3a5c4af32bf (MD5) | en |
| dc.description.provenance | Made available in DSpace on 2024-01-12T18:03:06Z (GMT). No. of bitstreams: 1 SemensatoETAL_Lajer_2023-2.pdf: 1274576 bytes, checksum: 0e0e7b97e41361a07200c3a5c4af32bf (MD5) Previous issue date: 2023-12-28 | en |
| dc.language | eng | pt_BR |
| dc.publisher | Universidade Federal do Espírito Santo | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | São Mateus | pt_BR |
| dc.publisher.initials | Ufes | pt_BR |
| dc.relation.ispartof | Latin American Journal of Energy Research | pt_BR |
| dc.rights | Acesso Aberto | pt_BR |
| dc.subject | Allocation of passive filters | pt_BR |
| dc.subject | unbalanced distribution network | pt_BR |
| dc.subject | ideal compensation method | pt_BR |
| dc.subject | harmonic components | pt_BR |
| dc.subject | distributed generation | pt_BR |
| dc.subject.cnpq | CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA | pt_BR |
| dc.title | Passive filters allocation in unbalanced distribution network with high penetration of distributed generation | pt_BR |
| dc.title.alternative | Alocação de filtros passivos em rede de distribuição desequilibrada com alta penetração de geração distribuída | pt_BR |
| dc.type | Artigo de Periódico | pt_BR |
| ifg.linktrabalho | https://periodicos.ufes.br/lajer/article/view/42149 | pt_BR |
| Aparece nas coleções: | Artigos de Periódicos Científicos | |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| Semensato_ etal | 1,24 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.