Use este identificador para citar ou linkar para este item:
https://repositorio.ifg.edu.br/handle/prefix/1647| Tipo: | Trabalho de Conclusão de Curso |
| Título: | Análise das instalações elétricas do bloco b do IFG - Câmpus Aparecida de Goiânia: estudo de caso |
| Título(s) alternativo(s): | Analysis of electrical installations in block b of the IFG - Campus Aparecida de Goiânia: case study. |
| Autor(es): | Porto, João Guilherme França Silva, Paulo Junio da |
| Primeiro Orientador: | Silva, Moisés Gregório da |
| metadata.dc.contributor.referee1: | Silva, Moisés Gregório da |
| metadata.dc.contributor.referee2: | Andrade, Ricardo Fernandes de |
| metadata.dc.contributor.referee3: | Moraes Junior, Gentil Mota de |
| Resumo: | Essa pesquisa teve por objetivo realizar uma análise das instalações elétricas em baixa tensão de uma edificação, tendo em vista o grande impacto que esse assunto pode causar em termos de funcionamento elétrico e na segurança das pessoas. A análise foi fundamentada na NBR 5410/2004, Norma Regulamentadora 10, Norma Regulamentadora 18, NBR ISO/CIE 8995/2013 e nos autores Creder (2016) e Júnior (2013). O estudo de caso foi realizado no IFG câmpus Aparecida de Goiânia. Para tanto, a metodologia utilizada foi a inspeção visual, análise de projetos e medições com multímetro digital, alicate amperímetro e luxímetro, que possibilitou a elaboração de uma lista de verificação com 45 avaliações. Através dessa lista, averiguou-se 36 requisitos voltados diretamente para as instalações elétricas de baixa tensão e 9 requisitos com relação à iluminação em ambientes de trabalho. Foi possível concluir que a edificação atende 26 dos itens avaliados, ou seja mais da metade, entretanto, alguns requisitos com não conformidade oferecem considerável grau de risco para os usuários da edificação, como: falta de plano de emergência que envolvam eletricidade, ausência do Prontuário de Instalações Elétricas, ausência de inspeção ou manutenção semestral no Sistema de Proteção contra Descargas Atmosféricas. |
| Abstract: | This research aimed to carry out an analysis of the low-voltage electrical installations of a building, because of the great impact that this subject can cause in terms of electrical functioning and people's safety. The analysis was based on NBR 5410/2004, Regulatory Standard 10, Regulatory Standard 18, NBR ISO/CIE 8995/2013, and on the authors Creder (2016) and Júnior (2013). The case study was carried out at the IFG campus Aparecida de Goiânia. For this purpose, the methodology used was visual inspection, project analysis, and measurements with a digital multimeter, ammeter pliers, and luxmeter, which enabled the elaboration of a checklist with 45 evaluations. Through this list, 36 requirements were found directly aimed at low voltage electrical installations and 9 requirements regarding lighting in work environments. It was possible to conclude that the building is approved in 26 of the evaluated items, that is, more than half, however, some requirements with non-compliance offer a considerable degree of risk for the users of the building, such as lack of an emergency plan involving electricity, absence of the Electrical Installations Handbook and the non-inspection or half-yearly maintenance in the Atmospheric Discharge Protection System. |
| Palavras-chave: | Instalações elétricas em baixa tensão NBR 5410 Segurança na construção civil |
| CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::CONSTRUCAO CIVIL |
| Idioma: | por |
| País: | Brasil |
| Editor: | Insitituto Federal de Educação, Ciência e Tecnologia de Goiás |
| Sigla da Instituição: | IFG |
| metadata.dc.publisher.department: | Câmpus Aparecida de Goiânia |
| Citação: | PORTO, João Guilherme França; SILVA, Paulo Junio da. Análise das instalações elétricas do bloco b do IFG - Câmpus Aparecida de Goiânia: estudo de caso. 2022. 19 f. Trabalho de Conclusão de Curso (Graduação em Engenharia Civil) – Instituto Federal de Educação, Ciência e Tecnologia de Goiás, Câmpus Aparecida de Goiânia, 2022. |
| Tipo de Acesso: | Acesso Aberto |
| URI: | http://repositorio.ifg.edu.br:8080/handle/prefix/1647 |
| Data do documento: | 20-Dez-2022 |
| Aparece nas coleções: | Bacharelado em Engenharia Civil |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| tcc João Porto_Paulo Silva.pdf | 2,8 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.